详细信息
Optimal design of a micro combined CHP system applying PEM fuel cell as initial mover with utilization of Developed Pathfinder Optimizer ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Optimal design of a micro combined CHP system applying PEM fuel cell as initial mover with utilization of Developed Pathfinder Optimizer
作者:Bai, Rulin[1];Jermsittiparsert, Kittisak[2,3,4]
第一作者:Bai, Rulin
通讯作者:Jermsittiparsert, K[1]
机构:[1]Donghua Univ, Shanghai 200051, Peoples R China;[2]Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam;[3]Duy Tan Univ, Fac Informat Technol, Da Nang 550000, Vietnam;[4]Henan Univ Econ & Law, MBA Sch, Zhengzhou 450046, Henan, Peoples R China
第一机构:Donghua Univ, Shanghai 200051, Peoples R China
通讯机构:[1]corresponding author), Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam.
年份:2020
卷号:6
起止页码:3377-3389
外文期刊名:ENERGY REPORTS
收录:;EI(收录号:20205109655307);Scopus(收录号:2-s2.0-85097784134);WOS:【SCI-EXPANDED(收录号:WOS:000602734500014)】;
语种:英文
外文关键词:Optimization; Combined cooling; Heating and power source; PEM fuel cell; Ratio of carbon dioxide emission; Yearly overall cost-saving; Developed Pathfinder (DPF) optimizer
摘要:The use of Combined Cooling, Heating, and Power (CHP) system, as one of the possible solutions to increase efficiency and to reduce environmental pollution, is rapidly increasing in residential units. The primary mover of combined CHP-based buildings can be based on gas-burning engine, micro turbine, fuel cell (FC), or a sterling engine. Characteristics such as higher effectiveness, very lower pollution, without moving parts, modularity, and extensive suffering for FCs have led many developed countries to support FC development at the top of their budget plans. In the present study, to reduce the power demand, a new optimal arrangement has been suggested for the combined CHP system in a residential building in Yazd, Iran. The research gives a Developed version of Pathfinder Optimizer (DPF) to optimize the combined CHP configuration by considering the highest unified operation for the suggested combined CHP system. A comparison of the outcomes of the suggested method with the SMS algorithm and basic PF algorithm is carried out to indicate the algorithm superiority. The final results show that using the considered method decreases the ratio of carbon dioxide emission ratio (RCDE). The results also showed that based on the proposed method, yearly overall cost-saving (YOCS) has the minimum effect on the combined effectiveness. (C) 2020 The Authors. Published by Elsevier Ltd.